SECTION 08342
FIBERGLASS REINFORCED DOOR AND DOOR FRAME SYSTEMS
NOTE ** This section is based on fiberglass reinforced
plastic doors and fiberglass door frames for
corrosive environments produced by:
NOTE ** FIB-R-DOR Division of Advance Fiberglass, Inc.
NOTE ** P.O. Box 13268
NOTE ** Maumelle, AR 72113
NOTE ** Tel: (800) 342-7367
NOTE ** Fax: (501) 758-9496
NOTE **
NOTE ** FIB-R-DOR custom fabricates doors for each project.
NOTE ** FIB-R-DOR is USDA accepted.
NOTE **
NOTE ** FIB-R-DOR produces both non-rated and labeled fire-
rated fiberglass doors.
NOTE **
NOTE ** SECTION 08342 - FIBERGLASS REINFORCED DOOR AND DOOR
FRAME SYSTEMS, Copyright 1998, The Architect's
Catalog, Inc.
PART 1 GENERAL
1.1 SECTION INCLUDES
NOTE ** Delete items below not required for project.
A. Fiberglass Reinforced Plastic (FRP) Doors.
B. Fiberglass Door Frames.
C. Fiberglass Louvers.
D. Fiberglass Reinforced Plastic (FRP) Transoms.
1.2 RELATED SECTIONS
NOTE ** Delete any sections below not relevant to this
project; add others as required.
A. Section 08710 - Door Hardware.
B. Section 08800 - Glazing.
1.3 REFERENCES
NOTE ** Delete references from the list below that are not
actually required by the text of the edited
section.
A. ASTM D 523 - Standard Test Method for Specular Gloss.
B. ASTM D 635 - Standard Test Method for Rate of Burning
and/or Extent and Time of Burning of Self-Supporting
Plastics in a Horizontal Position.
C. ASTM E 84 - Standard Test Method for Surface Burning
Characteristics of Building Materials.
D. ASTM E 152 - Standard Methods of Fire Tests of Door
Assemblies.
E. NFPA 252 - Standard Methods of Fire Tests of Door
Assemblies.
F. SDI 100 - Recommended Specifications for Steel Doors and
Frames.
G. UL 10B - Standard for Fire Tests of Door Assemblies.
H. UL 305 - Standard for Panic Hardware.
1.4 SYSTEM DESCRIPTION
A. Performance Requirements:
NOTE ** Delete paragraph below if options in the two sub-
paragraphs are not applicable to project.
1. Door opening assemblies:
NOTE ** The following two sub-paragraphs are options;
delete if not applicable to project.
a. Maximum flame spread 25 in accordance with ASTM E
84, self-extinguishing in accordance with ASTM D
635.
b. USDA accepted.
NOTE ** Delete one or both paragraphs below if not
applicable to project.
2. Fire rated assemblies: Comply with requirements of
UL10B, NFPA 252, and ASTM E 152; UL ______ rating,
with doors and frames bearing rating labels.
3. Fire rated assemblies: Comply with requirements of
UL10B, NFPA 252, and ASTM E 152; UL ratings indicated
on drawings, with doors and frames bearing rating
labels.
1.5 SUBMITTALS
A. Submit under provisions of Section 01300.
B. Product Data: Manufacturer's printed product data
indicating characteristics of products specified in this
Section.
C. Shop Drawings:
1. Plans: Indicate location of each door opening
assembly in project.
2. Elevations: Dimensioned elevation of each type door
opening assembly in project; indicate sizes and
locations of door hardware, and lites and louvers, if
specified.
3. Details: Installation details of each type
installation condition in project; indicate
installation details of glazing, if specified.
4. Schedule: Indicate each door opening assembly in
project; cross-reference to plans, elevations, and
details.
D. Selection Samples: Manufacturer's standard color chips.
E. Verification Samples: Two (2) samples to verify color
match.
F. Manufacturer's Instructions: Printed installation
instructions for door opening assemblies.
G. Warranty Documents: Manufacturer's standard warranty
documents, executed by manufacturer's representative,
countersigned by Contractor.
1.6 DELIVERY, STORAGE, AND HANDLING
A. Packing, Shipping, Handling and Unloading: Package door
opening assemblies in manufacturer's standard containers.
B. Store door assemblies in manufacturer's standard
containers, on end, to prevent damage to face corners and
edges.
1.7 WARRANTY
A. Manufacturer's Warranty: Manufacturer's 10-year warranty
against failure due to corrosion from specified
environment.
PART 2 PRODUCTS
2.1 MANUFACTURERS
A. Acceptable Manufacturers: FIB-R-DOR Division of Advance
Fiberglass, Inc.; P.O. Box 13268, Maumelle, AR 72113;
ASD. Tel: (800) 342-7367, Fax: (501) 758-9496
NOTE ** Delete one of the two paragraphs below; coordinate
with Division 01 requirements.
B. Requests for substitutions will be considered in
accordance with provisions of Section 01600.
C. Substitutions: Not permitted.
D. Manufacturer must have been in the business of
manufacturing fiberglass doors and frames for a minimum
of ten (10) years and be able to provide documented
references of performance.
2.2 MATERIALS
A. Fiberglass Mat: Minimum 1.5 ounces per square foot.
B. Resins: Manufacturer's formulation for fabricating units
to meet specified requirements.
C. Anchors: Manufacturer's standard stainless steel
expansion anchors for existing openings, and stainless
steel masonry tee anchors for new construction.
D. Fasteners: Stainless steel.
E. Glazing: Type specified in Section 08800; factory
installed.
2.3 MANUFACTURED UNITS
NOTE ** Delete paragraphs specifying products not required
for project.
A. Non-rated Fiberglass Reinforced Plastic (FRP) Doors:
1. Thickness: 1-3/4 inches.
2. Thermal Insulating Value: 'R' factor 11.
3. Construction:
a. Core: End-grain balsa wood, resin-impregnated.
b. Door Plates: Molded in one continuous piece,
resin reinforced with hand-laid glass fiber mat,
nominal 1/8 inch thick, minimum 15 mil gel-coated
surface.
c. Door Edges: Minimum three (3) layers resin-
reinforced glass fiber mat, nominal 3/8 inch
thick, machine tooled.
4. Sizes: Indicated on drawings.
5. Finish: Smooth gloss surface, minimum value 88 in
accordance with ASTM D 523.
NOTE ** Consult manufacturer's color chart for available
colors.
6. Color: ________.
B. Fire-rated Fiberglass Reinforced Plastic (FRP) Doors:
1. Thickness: 1-3/4 inches.
2. Thermal Insulating Value: 'R' factor 11.
3. Construction:
a. Core: Fire-resistant mineral core.
b. Door Plates: Molded in one continuous piece,
resin reinforced with hand-laid glass fiber mat,
nominal 1/8 inch thick, minimum 25 mil gel-coated
surface.
c. Door Edges: Minimum two (2) layers resin-
reinforced glass fiber mat, nominal 1/4 inch
thick, machine tooled.
4. Sizes: Indicated on drawings.
5. Finish: Smooth gloss surface, minimum value 88 in
accordance with ASTM D 523.
NOTE ** Consult manufacturer's color chart for available
colors.
6. Color: ________.
C. Non-rated Fiberglass Frames:
1. Construction: One-piece pultruded fiberglass
reinforced plastic, minimum 1/4 inch wall thickness,
jamb-to-head joints mitered and reinforced with FRP
clips and stainless steel fasteners; conforming to
SDI requirements for performance equivalent to 16
gage steel frames.
2. Frame profile: 5-3/4 inches deep, 2 inches wide
face; double rabbeted with 5/8 inch high stop.
3. Sizes: Indicated on drawings.
4. Finish: Satin finish, with true and consistent color
throughout frame thickness.
NOTE ** Selections below represent manufacturer's standard
available colors.
5. Color: White pigmented.
6. Color: Gray pigmented.
NOTE ** Standard frames can be gelcoated if custom color is
required.
7. Color: _____________ gelcoated.
D. Fire-rated Frames: UL approved, and as follows:
NOTE ** Select frame construction type in one of the three
following paragraphs.
1. Construction: Type 304 stainless steel.
2. Construction: Cold-rolled steel, primer finish.
3. Sizes: For door sizes and frame profiles indicated
on drawings.
E. Frame Anchors: Types recommended by manufacturer for
project conditions.
NOTE ** Delete paragraph below if louvers not required in
non-rated doors.
F. Louvers in Non-rated Doors:
1. Construction: Molded solid vanes; pultruded
fiberglass reinforced plastic construction.
2. Sizes: Indicated on drawings.
3. Finish: Satin finish, with true and consistent color
throughout frame thickness.
NOTE ** Selections below represent manufacturer's standard
available colors.
4. Color: White pigmented.
5. Color: Gray pigmented.
NOTE ** Delete paragraph below if louvers not required in
fire-rated doors.
G. Louvers in Fire-rated Doors: UL approved for indicated
fire resistance rating.
NOTE ** Delete paragraph below if lites not required in non-
rated doors.
H. Lites in Non-rated Doors:
1. Stops: Pultruded fiberglass reinforced plastic
construction.
2. Glazing: Specified in Section 08800.
3. Sizes: Indicated on drawings.
4. Fasteners: Stainless steel screws.
NOTE ** Delete paragraph below if lites not required in
fire-rated doors.
I. Lites in Fire-rated Doors: UL approved, and as follows:
NOTE ** Select stop type in one of the three following
paragraphs.
1. Frames: Type 304 stainless steel.
2. Frames: Cold-rolled steel, gray primer finish.
3. Frames: Cold-rolled steel, bronze baked enamel
finish.
4. Glazing: Specified in Section 08800.
5. Sizes: Indicated on drawings.
6. Fasteners: Stainless steel screws.
NOTE ** Delete paragraph below if transoms not required.
J. Fiberglass Reinforced Plastic (FRP) Transoms: Match
adjacent door construction and color.
NOTE ** Retain one of the following two paragraphs; if
specifying door hardware supplied by door
manufacturer, edit second paragraph for project
conditions.
K. Door Hardware: Specified Section 08710.
L. Door Hardware: Supplied by door manufacturer, UL-listed
for fire-rated openings, and as follows:
1. Hinges: Location and quantity indicated on approved
shop drawings, and as follows:
a. Type: Full-mortise, ball-bearing stainless steel
butts, 4-1/2 inches by 4-1/2 inches template;
stainless steel fasteners.
b. Acceptable product: Fib-R-Dor BB51.
NOTE ** Select closer required in one of the following
three paragraphs.
2. Closers:
a. Type: Standard service.
b. Acceptable product: International 984.
3. Closers:
a. Type: Severe service.
b. Acceptable product: LCN 4041-EDA-SRI-ALXTB.
4. Closers:
a. Type: Stainless steel arms.
b. Acceptable product: Norton 1604SS.
5. Kick Plates: 18 gage stainless steel, with beveled
edges and brushed finish; stainless steel fasteners.
NOTE ** Select lockset and latchset grade requirement in
one of the following two paragraphs; Grade 2 is
standard service, Grade 1 is severe service.
6. Locksets and Latchsets: Ball knob, exposed surfaces
of stainless steel, Grade 2.
7. Locksets and Latchsets: Ball knob, exposed surfaces
of stainless steel, Grade 1.
8. Push/Pulls: Stainless steel, with beveled edges and
brushed finish, size 3-1/2 inches by 15 inches;
stainless steel fasteners.
9. Exit Devices:
a. Type: Conforming to UL 305; equipped with pull
handle and thumb latch.
b. Acceptable product: RIM 19-R Series.
2.4 FABRICATION
A. Fiberglass Reinforced Plastic (FRP) Doors:
1. Minimum glass fiber to resin ratio: 30 percent.
2. Mortise for lockset, and recess for strike plate in
lock stile.
3. Embed steel reinforcement for hinges in fiberglass
matrix; provide for hinge leaf recesses in hinge
stile.
B. Fiberglass Frames:
1. Mortise for lock strike, and recess for strike plate
in lock jamb.
2. Reinforce for hinges and other indicated hardware.
PART 3 EXECUTION
3.1 EXAMINATION
A. Verification of Conditions:
1. Openings are correctly prepared to receive doors and
frames.
2. Openings are correct size and depth in accordance
with shop drawings.
B. Installer's Examination:
1. Have installer examine conditions under which
construction activities of this section are to be
performed and submit written report if conditions are
unacceptable.
2. Transmit two copies of installer's report to
Architect within 24 hours of receipt.
3. Beginning construction activities of this section
before unacceptable conditions have been corrected is
prohibited.
4. Beginning construction activities of this section
indicates installer's acceptance of conditions.
NOTE ** Delete paragraph below if glazed lites are not
specified.
C. Verify that glazing has been factory-installed.
3.2 INSTALLATION
A. Install door opening assemblies in accordance with shop
drawings, SDI 100, and manufacturer's printed
installation instructions, using installation methods and
materials specified in installation instructions.
B. Installation of door hardware is specified in Section
08710.
C. Install door hardware in accordance with manufacturer's
printed instructions, using through-bolts to secure
surface applied hardware.
D. Site Tolerances: Maintain plumb and level tolerances
specified in manufacturer's printed installation
instructions.
3.3 ADJUSTING
A. Adjust doors in accordance with door manufacturer's
maintenance instructions to swing open and shut without
binding, and to remain in place at any angle without
being moved by gravitational influence.
B. Adjust door hardware to operate correctly in accordance
with hardware manufacturer's maintenance instructions.
3.4 CLEANING
A. Clean surfaces of door opening assemblies and sight-
exposed door hardware in accordance with manufacturer's
maintenance instructions.
3.5 PROTECTION OF INSTALLED PRODUCTS
A. Protect door opening assemblies and door hardware from
damage by subsequent construction activities until final
inspection.
END OF SECTION